Silfluo

Room-Temperature Curable Coatings

SILZ-RT6 — Room-Temperature Curable Silazane Coating

SILZ-RT6 is a room-temperature curable silazane coating that brings ceramic-like protection to jobs where an oven is not an option. The one-component system cures ambient to a ≥4H, non-yellowing film with covalent adhesion, 30-day salt spray endurance and a water contact angle above 105° — built for on-site repair, maintenance and outdoor protective work.

Samples
from 1 kg
MOQ
No strict minimum
Lead time
~14 working days
Documents
TDS · SDS · COA
Discuss Your Project
Silfluo SILZ-RT6 room-temperature curable silazane coating

Product Overview

The formulation pairs a polysilazane film-former with specialized diluents, inhibitors and leveling additives, so it applies like paint and cures like a thin ceramic. Service runs below 150 °C continuously with short-term substrate-dependent exposure to 800 °C, and 30-day immersion in 5% NaCl, H₂SO₄ and HNO₃ leaves the film uncorroded.

Formulated with compatible fillers, RT6-based systems reach performance comparable to our SILZ-HT21 line — acid, alkali, UV and cracking resistance — which is why it serves aerospace, petrochemical, metallurgy and power-generation maintenance programs as the entry point of the room-temperature series.

Key Benefits

Cures on site, no oven

Full ambient cure with an optional 180 °C accelerated schedule (30 minutes) when a line oven exists.

Generous film window

20–200 µm dry film in a single coat — the most forgiving build range in the series, suited to repair and field work.

30-day chemical immersion

5% NaCl, H₂SO₄ and HNO₃ for 30 days without corrosion; 30-day neutral salt spray without blistering or rust.

Hydrophobic, self-cleaning surface

>105° contact angle sheds water and grime for outdoor anti-aging duty.

Typical Applications

  • Coating repair & maintenance
  • Wear/fire-resistant protection
  • Outdoor hydrophobic self-cleaning surfaces
  • Antibacterial skin-contact topcoats

Solution guides: Transparent, Hard & Easy-Clean Surface Protection

Technical Data

Coating Performance
Test ItemPerformance IndicatorTest Method
AppearanceLight yellow to colorless transparent liquid
Density0.87 ± 0.02 g/mL
Solid Content (120 ± 2°C)>40%
Pencil Hardness≥4H
AdhesionGrade 0
Neutral Salt Spray Resistance30 d: no blistering, cracking or rust
Artificial Aging Resistance30 d: no chalking or cracking, slight color change
Chemical Resistance5% NaCl / H₂SO₄ / HNO₃, 30 d: no corrosion
Water Contact Angle>105°
Application Parameters
Dry Film Thickness20–200 µm (single coat, ≤200 µm)
Cure @25 °C (RH 70%)Surface dry 2 h · full cure >5 d
Heat Cure Option180 °C: surface dry 6 min, full cure 0.5 h
Working Time (after opening)6 h
Service Temperature<150 °C continuous; short-term to 800 °C (substrate-dependent)
Storage / Shelf Life5–30 °C · 6 months

Values from the SILZ-RT6 technical data sheet. Complete TDS with test conditions available on request.

Curing & Processing Guidance

Prepare surfaces to Sa 2.5 (minimum St 3, no mill scale), degrease and dry. Shake the container thoroughly and filter through a 400-mesh sieve before use.

Spray with a 0.5–1.0 mm nozzle in one coat, keeping dry film at or below 200 µm. Use opened material within 6 hours.

At room temperature the film is surface-dry in 1–3 hours (temperature-dependent) and fully cured in 3–7 days; at 180 °C full cure takes 30 minutes. Humidity participates in cure — the 70% RH reference schedule shortens in humid conditions and stretches in very dry air.

Substrate Compatibility

Steel, stainless steel, aluminum and common industrial metals after standard preparation; also masonry-class surfaces in maintenance duty. For substrate-specific systems — especially where short-term high-temperature excursions are expected — confirm the formulation with our engineers.

SILZ-RT6 — Purchasing & Application FAQ

How does SILZ-RT6 differ from SILZ-RT7?

RT6 is the maintenance-grade workhorse: ≥4H hardness, higher build tolerance and the lowest cost of entry. RT7 is the premium clearcoat: ≥8H hardness, >110° contact angle and 500 °C non-yellowing service. Choose RT6 for repair and general protection, RT7 where hardness and long-term heat exposure dominate.

Can I speed up the multi-day ambient cure?

Yes — any heat helps. The formal accelerated schedule is 180 °C for 30 minutes; lower oven temperatures shorten cure proportionally. Ambient humidity also accelerates cure since moisture drives the reaction.

Is RT6 suitable for surfaces that see occasional flame or heat spikes?

Short-term exposure up to 800 °C is possible depending on substrate and film design. For repeated or continuous high-temperature duty, use the SILZ-HT ceramic line instead — RT6's continuous rating is below 150 °C.

TDS / SDS / COA & Samples

Technical Data Sheet, Safety Data Sheet and batch Certificate of Analysis are available for SILZ-RT6, and a COA accompanies every shipment. Evaluation samples ship with starting-parameter guidance.

Packaging: Available in 1 kg, 2 kg, 5 kg and 25 kg pails. Shelf life 6 months at 5–30 °C in the original sealed container.

SDS & batch COA on request · Reply within 1 business day.