Fluorinated electronic coatings are fluoropolymer solutions in a non-flammable fluorinated carrier. Applied by dip, spray, roll or blade, the carrier flashes off in seconds to minutes and leaves a film of roughly 0.5 to 10 µm with a static water contact angle of at least 110°, thin enough to protect fine-pitch assemblies and precision parts without changing their fit.
The LC-FC grades share this chemistry and the same 2%, 5% and 10% solids options. They differ in how coverage is inspected and how much oil repellency you need: LC-FC130 dries matte, LC-FC181/183 gives the highest oleophobicity, LC-FC260 leaves a yellow tint visible without a lamp, and LC-FC633 carries a fluorescent tracer. Where a design needs mechanical protection or a thick film, a conventional conformal coating is the better fit.
| Grade | Product | Film Type | Inspection Aid | Static Water Contact Angle | Surface Free Energy | Thermal Stability (1% mass loss) | Single-Coat Dry Film Thickness (2% / 5% / 10% grades) |
|---|---|---|---|---|---|---|---|
| LC-FC130 | Matte Fluorinated Conformal Coating for Electronics | Matte type | None (matte film) | ≥110° | 10–12 mN/m | ~200 °C | 0.5–1.5 / 1.0–2.0 / 1.5–2.5 µm |
| LC-FC181/183 | High-Oleophobic Fluorinated Conformal Coating Series | High oleophobic type | Fluorescent tracer (LC-FC183 only) | ≥118° | 8–10 mN/m | ~260 °C | 0.5–1.5 / 1.5–2.5 / 3–10 µm |
| LC-FC260 | Fluorinated Conformal Coating with Yellow Visual Indicator | Yellow indicator type | Yellow tint visible in ambient light | ≥110° | 10–12 mN/m | ~280 °C | 1.0–1.5 / 1.0–2.5 / 2.0–3.5 µm |
| LC-FC633 | Fluorinated Conformal Coating with Fluorescent Inspection | Standard type | Fluorescent tracer | ≥110° | 10–11 mN/m | ~260 °C | 0.5–1.0 / 1.0–1.5 / 1.5–2.5 µm |
Comparison values from each product's TDS; “—” = not listed for that grade; see its product page and TDS.
LC-FC130 dries to a matte film with no inspection aid. LC-FC183 and LC-FC633 contain a fluorescent tracer for UV-lamp inspection. LC-FC260 keeps a yellow tint for at least 30 days, so coverage can be checked by eye in ambient light.
When oils, lubricants or skin oils are the contaminant, LC-FC181/183 is the reference: n-hexadecane contact angle ≥80° and surface free energy 8–10 mN/m. The other grades reach ≥70° (LC-FC130) or ≥75° (LC-FC260, LC-FC633).
Single coats range from about 0.5–1.5 µm at 2% solids to 1.5–3.5 µm at 10% for most grades; the 10% grade of LC-FC181/183 reaches 3–10 µm. Start from the lowest solids that gives continuous coverage on your part, then confirm by function testing.
Check service temperature against each grade: 1% mass loss occurs near 200 °C for LC-FC130 and 260–280 °C for the others. LC-FC130 also has a melting point of 25–30 °C, against 70–80 °C for LC-FC181/183, which matters on parts that run warm.
Only where a micron-level film is enough. LC-FC coatings repel water, oils and contaminants and keep contacts and clearances intact, but they do not give the mechanical protection or film build of a silicone, acrylic or UV-cured conformal coating. Tell us the failure mode and we will say which approach fits.
The fluorinated carrier has no flash point and a boiling range of 50–68 °C, so it evaporates quickly at room temperature. Use stainless-steel or PTFE-lined equipment and normal ventilation. The TDS lists the products as zero ODP and RoHS compliant.
They may be evaluated for this. The low surface energy film is designed to resist oil spreading, and the TDS lists epilame and lubricant anti-migration treatment as a potential use. No grade is specifically rated for migration control, so qualification with your lubricant and part is needed; LC-FC130 and LC-FC181 are the usual starting points.
Send us your substrate, application method and service conditions — our technical team replies within 1 business day.