Silfluo
Close-up of a skeleton mechanical watch with gold-tone gears, jewel bearings and polished hands

Application Solution

Precision Parts & WatchesEpilame and lubricant anti-migration coatings

≥80°

n-Hexadecane contact angle (LC-FC181/183)

0.5 µm

Thinnest single coat

8–10 mN/m

Lowest surface free energy

In watches, micro-motors and camera mechanisms, a tiny amount of lubricant has to stay exactly where it was placed. If the oil spreads along a pivot, gear or bearing surface, the contact runs short of lubricant and the migrating oil can contaminate optics, contacts or neighbouring parts. An epilame treatment lowers the surface energy around the lubricant so it stays in place.

The LC-FC fluorinated coatings may be evaluated for this role. They leave fluoropolymer films with single coats from about 0.5 µm, surface free energy as low as 8–10 mN/m and n-hexadecane contact angles of at least 70° to 80° depending on grade.

Their TDS lists epilame and lubricant anti-migration treatment, HDD read-head barriers and MEMS devices as potential uses, not validated ones. No LC-FC grade is specifically rated for migration control, so every programme starts with trials on your own parts and lubricant.

Service Conditions Covered

Typical partsWatch movements, micro-motors, camera and lens mechanisms · HDD magnetoresistive heads and MEMS devices as potential uses
Contaminant to controlLubricating oils that creep along metal and polymer surfaces away from the contact
Film build0.5–1.5 µm per coat at 2% solids, up to 3–10 µm for LC-FC181/183 at 10%
Surface propertiesSurface free energy 8–12 mN/m · n-hexadecane contact angle ≥70° to ≥80° · water contact angle ≥110°
ApplicationDip, spray, roll or blade; the carrier has no flash point and the film is tack-free in 30 s–2 min
Checking treated areasFluorescent tracer (LC-FC183, LC-FC633) or yellow tint visible in normal light (LC-FC260)

Recommended Products & Why

Grade Film Typen-Hexadecane Contact AngleSingle-Coat DFT (2% / 5% / 10%)1% Mass Loss Why this grade
LC-FC181/183 High oleophobic type≥80°0.5–1.5 / 1.5–2.5 / 3–10 µm~260 °C Strongest oil repellency in the range (n-hexadecane ≥80°, 8–10 mN/m) and the usual first trial for lubricant control; LC-FC183 adds fluorescence to check treated zones.
LC-FC130 Matte type≥70°0.5–1.5 / 1.0–2.0 / 1.5–2.5 µm~200 °C Colorless matte film at 0.5–2.5 µm per coat, a suggested starting point for transparent or appearance-sensitive parts; check its 25–30 °C melting point against part temperature.
LC-FC633 Standard type≥75°0.5–1.0 / 1.0–1.5 / 1.5–2.5 µm~260 °C Clear film with a fluorescent tracer, so small parts can be checked under UV for complete treatment; 0.5–1.0 µm per coat at 2% solids.
LC-FC260 Yellow indicator type≥75°1.0–1.5 / 1.0–2.5 / 2.0–3.5 µm~280 °C Yellow tint visible in normal light for at least 30 days, useful where treated parts are sorted or checked by eye during assembly.

Table values from each product's TDS; “—” = not listed in that TDS.

Surface Preparation & Application Principles

Clean parts thoroughly before treatment. Residual oil from machining or handling lowers the effect of the epilame before the lubricant is even applied.

Treat first, let the carrier flash off, then lubricate. Use the lowest solids grade that gives a continuous film, and keep application equipment in stainless steel or PTFE-lined materials.

Test oil spreading on treated and untreated parts side by side, with the lubricant, quantity and temperature profile of the real product, before deciding on a grade.

Mind part temperature: LC-FC130 melts at 25–30 °C and LC-FC181/183 at 70–80 °C, and 1% mass loss occurs near 200 °C (LC-FC130) to 280 °C (LC-FC260).

Applicability Boundaries & What We Confirm

  • Epilame, HDD and MEMS uses are potential applications in the TDS, not validated results; qualification on your parts is required.
  • No grade is rated for high purity, electronic grade or cleanroom-level residue, and we do not promise these without data.
  • Lubricants differ in how they behave on low-energy films, so results with one oil do not transfer automatically to another.
  • What we confirm: the part and its material, lubricant type and amount, allowed film thickness, cleaning process, application method and the migration test you will run.

Discuss your project with an engineer

Send your substrate, service conditions and current coating problem — we reply with a concrete system proposal within 1 business day.

Discuss Your Project

Reply within 1 business day