Applicable substrates:
Carbon steel, stainless steel, cast iron, aluminum alloy, titanium alloy, high-temperature alloy steel, microcrystalline glass, ceramics, cement, etc. Note: Different substrates require different coating formulations. Within a certain range, the formulation can be adjusted according to the specific application conditions of the substrate.
Applicable Temperature:
Suitable for outdoor applications below 400℃ and short-term high-temperature applications up to 600℃. The coating’s temperature resistance will vary depending on the substrate’s temperature resistance, and it is resistant to thermal shock and cold shock (Note: Different substrates require different products).
The main characteristics of the SILZ-150 coating are as follows:
Coating performance
| Test Items: |
Performance indicators |
Test Methods |
| Color and Appearance |
Pale yellow to colorless transparent liquid |
GB-T 1721-79 |
| Solid Content (120±2℃) |
>98% |
GB/T 1725-2007 |
| Density (g/mL) |
0.88±0.1 |
GB/T 6750-2007 |
| Adhesion |
≥6H |
GB/T 6739-2006 |
| Neutral Salt Spray Resistance |
0级 |
GB-T 9286-1998 |
| Hardness (pencil) |
>500h |
GB-T 10125-2021 |
| Hydrophobic Angle |
>100° |
GB/T 26490-2011 |
| Artificial Aging Resistance |
30d No rust, no powdering, no cracking, no discoloration |
GB-T 1865-2009 |
| Dielectric Strength (V/mm) |
≥105 |
ASTM-D149 |
| Resistance (Ωm) |
≥1012 |
GB/T 35856-2018 |
Construction basic parameters
| Item |
Parameters: |
Item |
Parameters |
| Coating Solids Content (%) |
>90 |
Volatility |
Solvent is volatile |
| Theoretical Coverage (m²/kg) |
6~8 |
Curing Temperature (℃) |
Room temperature |
| Dry Film Thickness (µm) |
20~50 |
Curing Time (h) |
>24 |
| Working Time (h) |
4 |
Maximum Instantaneous Temperature (℃) |
600 |
| Thinner |
Aromatics, lipids, ethers, etc. |
Recommended Operating Temperature (℃) |
-30 to 400 |
| Flash Point (℃) |
<22 (solvent flash point) |
Storage Temperature (℃) |
0-30 |
Special Notes:
This product is a single-component self-curing product. Once opened, the coating should be used within 4 hours. For longer application intervals, ensure all tools are clean to prevent adhesion. It is recommended to apply in one coat, with a dry film thickness not exceeding 50µm; otherwise, coating performance will decrease.
Standard Application Procedure: Surface Cleaning → Roughening → Cleaning and Blowing → SILZ-150 Treatment → Curing
Instruction Manual
- Roughening: Before coating, grind or sandblast the substrate surface to remove rust, dust, dirt, etc. Roughening significantly affects the coating effect; optimal Sa2.5, minimum St3 (no oxide scale) (GB/T 30790.4-2014), so please pay close attention.
- Cleaning: Use a specialized cleaner or degreaser to remove residual oil, dust, etc., from the roughened surface.
- Substrate Drying: Ensure the substrate surface is dry and clean before coating.
- Coating Mixing: This product is a single-component product. Take an appropriate amount and filter through a 120-mesh sieve as needed.
- Coating Application: For best appearance and uniformity, use a 1.0mm nozzle spray gun in the laboratory. The cured coating has some hydrophobic and oleophobic properties; therefore, repeated application is not recommended.
- Curing: After spraying, the coating should be surface dry in 2 hours, touch dry in more than 3 hours, and completely dry in more than 24 hours at room temperature.